From 1 December 2026, the Workplace Exposure Limits (WEL) list replaces the Workplace Exposure Standards (WES) list, following implementation into the WHS laws of each jurisdiction. Until 30 November 2026, the current WES values still apply. Most limits aren't changing, but some are being lowered or raised, some substances are being added and some are being listed differently.
Welding, cutting, grinding and spraying all put contaminants into the air, so every fabrication workshop should check where it stands, whether it's a small shop with a couple of machines or a large operation running multiple bays and shifts. Preparing comes down to four steps: identify, assess, control and verify.
What Hasn't Changed
The core duty for a person conducting a business or undertaking (PCBU) is the same: eliminate risks from airborne contaminants so far as is reasonably practicable, or otherwise minimise them. A WEL is a limit that must not be exceeded, but it isn't a line that marks exposure as "safe" or "unsafe". You must also consult your workers when identifying hazards and deciding on controls. Your welders usually know which jobs feel dusty, smelly or irritating.
Step 1: Identify What's in Your Workshop Air
Look at the work being done, not just what you buy. Welding, cutting, grinding and spraying can generate dusts, fumes, mists, vapours and gases, even when no hazardous chemical was purchased.
- Walk the Shop Floor: Go task by task through welding, cutting, grinding, finishing and cleaning, and note what each one puts in the air.
- Check Your Safety Data Sheets: SDSs list ingredients, relevant exposure values and recommended controls.
- Record What You Find: Note the contaminant, its form, the task, who is exposed, for how long and how often.
Then compare each contaminant against the current WES and incoming WEL using Safe Work Australia's summary of changes or its free Hazardous Chemical Information System (HCIS). Look beyond the number and check whether the exposure type, listing or notations have changed.
Two situations are worth flagging:
- Some Values Are Staying Put: Nine substances, including respirable crystalline silica, benzene and formaldehyde, stay at their current values from 1 December 2026.
- Skin Notations: Some substances can be absorbed through the skin. Exposure limits and respirators only deal with what's breathed in, so make sure gloves and protective clothing are suitable too.
Step 2: Assess Your Exposure
Check whether your existing risk assessments and air monitoring data still hold up. Older data may not reflect your current machines, processes or layout, and a result that sat comfortably under an old WES may be close to, or over, a lower WEL.
- Long Shifts: Most limits are an 8-hour time-weighted average (TWA), based on a 40-hour week. If your workshop runs 10- or 12-hour shifts, the TWA may need adjusting downwards. Get a qualified professional, such as an occupational hygienist, to calculate this.
- When Monitoring Is Required: The WEL change doesn't automatically require new air monitoring. It is required if you aren't certain, on reasonable grounds, whether exposure exceeds the limit, and a lower limit may create that uncertainty. Monitoring should be done by a competent person, and records must be kept for at least 30 years.
- Results Over the Limit: Improve your controls, protect workers in the meantime, then check again.
Step 3: Control the Risk
A changed limit doesn't mean every workshop needs new equipment, but where controls need to change, work through the hierarchy from the top:
- Elimination & Substitution: Remove the process that generates the contaminant, or use a less hazardous material or method.
- Isolation: Separate people from the source with enclosures or restricted areas.
- Engineering Controls: Local exhaust ventilation (LEV) captures fumes and dust at or near the source, before they reach the breathing zone. On-tool extraction captures dust directly at the tool.
- Administrative Controls & PPE: Procedures, task rotation and housekeeping support higher-order controls, with respiratory protective equipment (RPE) for any remaining exposure.
General ventilation on its own is rarely enough for significant sources, and a pedestal fan can even blow fumes towards workers. LEV only works if it's designed for the task, used correctly and kept in good condition, so build inspection and testing into your maintenance schedule. For housekeeping, wet wiping or a H-class vacuum removes settled dust, while dry sweeping or compressed air puts it back into the air.
Respiratory Protection Under the New Limits
Respirators reduce exposure; they don't eliminate it. RPE protection can only be counted towards WEL compliance once all reasonably practicable higher-order controls are in place or have been evaluated, and the RPE is selected, worn and maintained correctly.
- Check the Protection Level: If a limit drops or exposure is higher than expected, you may need a higher protection level or better upstream controls.
- Fit Test Tight-Fitting Respirators: Use a competent tester, such as a RESP-FIT accredited tester, before first use, when a new make or model is issued and when facial changes may affect the seal. A quick fit check doesn't replace a fit test.
- Beards & Facial Hair: For workers who can't get a reliable seal, a loose-fitting powered air-purifying respirator (PAPR) may be an option if it provides the required protection level.
Step 4: Verify Your Controls Are Working
Check that monitoring, extraction performance, fit tests, training and maintenance records are current, and follow up on complaints or unexpected results. Changes to processes, substances, equipment, production levels or shift patterns should send you back to Step 1.
Small Shop or Large Operation?
- Smaller Workshops: Start with Step 1. A current list of your contaminants may show that many of your limits aren't changing at all. If you're unsure where to start, some regulators offer free support. SafeWork NSW, for example, provides free advisory visits.
- Larger Operations: Where several contaminants are present, results are borderline or workers are on extended shifts, specialist occupational hygiene advice is worth seeking.
As an illustration, picture a small workshop with a solvent parts washer and a bench grinder. The solvent's WEL is lower than the current WES, and the only air monitoring is five years old and pre-dates the washer moving into a smaller room, so an occupational hygienist is engaged. The team looks at a less hazardous cleaning product, a lid and local extraction for the washer and on-tool extraction for the grinder, then re-samples to confirm the changes work.
How Orbimax Can Help
Orbimax supplies and hires tube and pipe welding equipment, tools and consumables to fabricators across Australia. When you review your controls, talk to us about:
- Cutting & Bevelling Equipment: GF pipe cutting and bevelling saws, clamshell (split frame) cutters and band saws, worth considering when you review hot or abrasive cutting methods.
- Welding Automation: Orbital welding systems, COBOT and the PX Passivation Workstation are worth considering when you review how and where welding is done.
- Gloves & Protective Clothing: Welding jackets, gloves, and eye and face protection to support skin protection alongside your other controls.
- Backed by ATOM Group: As part of ATOM Group, Orbimax can connect you with ATOM Safety, who can visit your workshop, review your current safety equipment and trial suitable respiratory protection with your team.
This article is general information only and isn't a substitute for a workplace-specific exposure assessment. Requirements vary between jurisdictions (Victoria operates under separate OHS laws), so check with your WHS regulator.